Richter GU/F Series Overflow Valves Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Příslušenství pro vodu Richter GU/F Series Overflow Valves. Richter GU/F Series Overflow Valves User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 22
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
INSTALLATION AND OPERATING MANUAL
Keep for future use!
This operating manual must be strictly observed before
transport, installation, operation and maintenance
Subject to change without notice.
Reproduction is generally permitted with indication of the source.
© Richter Chemie-Technik GmbH
9530-070-en Revision 00 Edition 10/2007
Series GU/F
Overflow and pressure relief
valve
DN 25 with certification
spring-loaded
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1 - Overflow and pressure relief

INSTALLATION AND OPERATING MANUAL Keep for future use! This operating manual must be strictly observed before transport, installation, operation and

Strany 2 - Relevant documents

Series GU/F Page 10 9530-070-en Revision 00 TM 6908 Edition 10/2007 Adraining facility must be provided at the lowest point in the pipe. This openi

Strany 3 - 1 Technical data

Series GU/F Page 11 9530-070-en Revision 00 TM 6908 Edition 10/2007 6.6 Grounding The valve must be grounded. The simplest solution is to use tooth

Strany 4 - 1.3 Tightening torques

Series GU/F Page 12 9530-070-en Revision 00 TM 6908 Edition 10/2007 7 Operation 7.1 Initial commissioning Normally, the valves have been tested for

Strany 5 - 2 Safety

Series GU/F Page 13 9530-070-en Revision 00 TM 6908 Edition 10/2007 8 Malfunctions  Overflow valve is leakingIs there foreign matter between the s

Strany 6 - 3.1 Intended use

Series GU/F Page 14 9530-070-en Revision 00 TM 6908 Edition 10/2007 9.3 Modification of the overflow valve If modifications to the valve are requi

Strany 7 - Series GU/F Page 7

Series GU/F Page 15 9530-070-en Revision 00 TM 6908 Edition 10/2007  Undo the hex. socket screws 914/1. Centre the spring bonnet 513 with internal

Strany 8 - 5.3 Return consignments

Series GU/F Page 16 9530-070-en Revision 00 TM 6908 Edition 10/2007 10 Drawings 10.1 Legend 100 body 117 thrust flange 124 pressure ring 204 plug

Strany 9 - 6 Installation

Series GU/F Page 17 9530-070-en Revision 00 TM 6908 Edition 10/2007 10.2 Sectional drawing GU

Strany 10 - 6.5 Direction of flow and

Series GU/F Page 18 9530-070-en Revision 00 TM 6908 Edition 10/2007 10.3 Views View X Detail Yupper spring plate Detail Z lower spring plate

Strany 11 - 6.7 Installation

Series GU/F Page 19 9530-070-en Revision 00 TM 6908 Edition 10/2007 10.4 Dimensional drawing Flange connecting dimensions:with flanges DIN EN 1092

Strany 12 - 7 Operation

Series GU/F Page 2 9530-070-en Revision 00 TM 6908 Edition 10/2007 List of Contents List of Contents ... 2 Re

Strany 13 - 8 Malfunctions

Prepared: CRQ/Lam on: Feb. 15, 06 Page: 1 QM No.: 0912-16-2001_en/4-06 Approved: CRQ/Zu on: Feb. 15, 06 of : 2Safety Information / Declaration

Strany 14 - TM 6908 Edition 10/2007

Declaration about the Contamination of Richter Pumps, -Valves and Components Prepared: CRQ/Lam on: Feb. 15, 06 Page: 2 QM No.: 0912-16-2001_en/4-

Strany 15 - 9.7 Tests

Landesbank Rheinland-Pfalz, Mainz  Kto. 110 145810 (BLZ 550 500 00) SWIFT: MALA DE 555 50  USt. Id. Nr. DE 811 127054 Sitz der Gesellschaft: Kempen

Strany 16 - 10 Drawings

Series GU/F Page 3 9530-070-en Revision 00 TM 6908 Edition 10/2007 1 Technical data Manufacturer: Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D

Strany 17 - 10.2 Sectional drawing GU

Series GU/F Page 4 9530-070-en Revision 00 TM 6908 Edition 10/2007 Body identification:The shell bears the following information in accordance with

Strany 18 - 10.3 Views

Series GU/F Page 5 9530-070-en Revision 00 TM 6908 Edition 10/2007 1.4 Screw-in tool for Nom. size [mm] [inch] Article-No. 25 1“ --- 40 1½“ 9568-

Strany 19 - 10.4 Dimensional drawing

Series GU/F Page 6 9530-070-en Revision 00 TM 6908 Edition 10/2007 2.1 Intended use Richter overflow valves of the GU series are pressure-maintai

Strany 20

Series GU/F Page 7 9530-070-en Revision 00 TM 6908 Edition 10/2007 Adifference is made between two cases for the use of chargeable liquids (conduct

Strany 21 - Richter Pumps, -Valves

Series GU/F Page 8 9530-070-en Revision 00 TM 6908 Edition 10/2007 5 Transport, storage and disposal It is imperative, for all transport work, to o

Strany 22 - () () - () () ()

Series GU/F Page 9 9530-070-en Revision 00 TM 6908 Edition 10/2007 5.4 Disposal Parts of the valve may be contaminated with medium which is detrim